System Configuration
Rated Voltage: 240V AC / 415V AC (50/60Hz)
Current Ratings : 63A
Breaking Capacity: 10kA (10000A) as per IS/IEC 60898-1:2015
Tripping Curves: C-Curve
Pole Configurations : Double Pole
Mounting Standard: 35mm DIN Rail (IEC 60715)
<p><span style="font-family:Arial,Helvetica,sans-serif"><span style="font-size:16px">Miniature Circuit Breakers provide automatic protection against overload and short-circuit conditions in low-voltage electrical installations. Designed for residential, commercial, and light industrial applications with rapid fault interruption capability.</span></span></p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif"><strong> Maasarent MCB Double Pole 63A C-Curve | High-Performance Electrical Protection </strong></span></span></p>
<p> </p>
<p style="text-align:justify"><span style="font-family:Arial,Helvetica,sans-serif"><span style="font-size:16px"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> High-Speed Fault Interruption: Features a rapid arc quenching matrix that guarantees complete fault clearance within just one half-cycle.</span></span></p>
<p style="text-align:justify"><span style="font-family:Arial,Helvetica,sans-serif"><span style="font-size:16px"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> Trip-Free Safety Principle: Built with an advanced safety override mechanism-the breaker will successfully trip and cannot be held closed against an active electrical fault.</span></span></p>
<p style="text-align:justify"><span style="font-family:Arial,Helvetica,sans-serif"><span style="font-size:16px"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> IP20 Touch-Safe Design: Equipped with finger-safe terminal protection as a standard safety configuration to protect installers and maintenance teams.</span></span></p>
<p style="text-align:justify"><span style="font-family:Arial,Helvetica,sans-serif"><span style="font-size:16px"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> Visual Trip Indication: Includes a highly visible, clear ON / OFF / TRIP position status indicator for swift diagnostic monitoring.</span></span></p>
<p style="text-align:justify"><span style="font-family:Arial,Helvetica,sans-serif"><span style="font-size:16px"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> Dual Thermal-Magnetic Protection: Combines a responsive bi-metallic strip for minor overloads with a robust electromagnetic solenoid for immediate short-circuit protection.</span></span></p>
<p style="text-align:justify"> </p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif"><strong>How it Works: Precision Tripping Technology</strong></span></span></p>
<p> </p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif">The breaker utilizes a synchronized thermal-magnetic dual principle:<br />
<img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> Thermal Operation (Overload Protection): For moderate, sustained overloads, the internal bimetallic strip gradually heats up, bends, and safely releases the latch mechanism to open the main contacts.<br />
<img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> Magnetic Operation (Short-Circuit Protection): In the event of a high overload or sudden short circuit, the internal electromagnetic solenoid activates instantly, driving a high-speed plunger to release the latch mechanism and break the circuit immediately. Versatile Applications.</span></span></p>
<p> </p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif"><strong>Maasarent MCBs are certified and optimized for a wide array of setups:</strong></span></span></p>
<p> </p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> <strong>Residential:</strong> Home distribution boards, lighting networks, and appliance protection.</span></span></p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> <strong>Commercial:</strong> Office complexes, retail spaces, and server rooms.</span></span></p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /><strong> Industrial Panels</strong>: Control setups, machinery circuits, and distribution panel boards.</span></span></p>
<p><span style="font-size:16px"><span style="font-family:Arial,Helvetica,sans-serif"><img alt="yes" src="https://maasarent.com/admin/bower_components/ckeditor/plugins/smiley/images/thumbs_up.png" style="height:23px; width:23px" title="yes" /> <strong>Power Circuits: </strong>High-load lighting setups and dedicated power utility distribution.</span></span></p>
Your email address will not be published. Required fields are marked *