Technical Specification
Product Code MCBTPN-C006-C032
Product Type Triple Pole + Neutral Miniature Circuit Breaker (TPN MCB)
Pole Configuration 3 Pole + Neutral (4 Pole)
Current Ratings 6A, 10A, 16A, 20A, 25A, 32A
Tripping Curve C Curve
Protection Type Overload & Short Circuit Protection
Rated Voltage 415V AC
Frequency 50/60 Hz
Breaking Capacity 6kA / 10kA*
Trip Mechanism Thermal-Magnetic
Mounting Type DIN Rail Mounting
Terminal Type Finger-Safe Terminals
Housing Material Flame Retardant Engineering Plastic
Neutral Switching Yes (TPN Configuration)
Standard IS/IEC 60898-1
MCBTPN-C006-C032 is a Triple Pole + Neutral Miniature Circuit Breaker with C Curve tripping characteristic and current ratings from 6A to 32A. It provides reliable overload and short-circuit protection for three-phase inductive and mixed-load systems with neutral isolation.
The MCBTPN-C006-C032 Triple Pole + Neutral Miniature Circuit Breaker (TPN MCB) is engineered for comprehensive protection of three-phase electrical distribution systems requiring neutral switching. With a C Curve tripping characteristic, it is suitable for circuits with moderate inrush currents such as motors, pumps, compressors, HVAC systems, transformers, and industrial equipment.
This device provides simultaneous protection and isolation of three phases along with the neutral conductor, ensuring complete circuit disconnection during fault conditions and maintenance operati
Available in 6A to 32A current ratings
Triple Pole and Neutral (TPN) configuration for complete 3-phase + neutral protection
C Curve tripping characteristic (5–10× rated current), suitable for inductive and moderate inrush loads such as motors and HVAC systems
Thermal-magnetic trip mechanism for fast overload and short-circuit response
DIN rail mounting for quick and secure installation
Compact modular design for distribution boards
Flame-retardant thermoplastic housing for enhanced safety
High breaking reliability under fault conditions
Finger-safe terminals for improved installation safety
Positive ON/OFF trip indication
Complies with IEC 60898-1 / IS 8828 standards
Three-phase residential distribution boards
Commercial electrical installations
Industrial control panels
Motor and pump circuits
HVAC and air conditioning systems
Generator distribution panels
Office and commercial buildings
Retail and infrastructure electrical systems
Electrical switchgear assemblies
Low-voltage power distribution systems
Small machinery and equipment protection
Utility and backup power circuits
Building electrical infrastructure
Mixed load three-phase circuits
General-purpose circuit protection
Your email address will not be published. Required fields are marked *